Customization: | Available |
---|---|
Type: | Currrent |
Output Signal Type: | Analog Output |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter | Conditions | ACM-I000 |
Measuring Axis | X, Y, Z (optional) | |
Accuracy | Vibration velocity | 1mm/s |
Vibration angle | 0.001°/s | |
Vibration amplitude | 0.001mm | |
Vibration frequency | 1HZ | |
Temperature calibration | -40-85ºC | |
Measurement range | Vibration velocity (0-50mm/s), Vibration angle (0-180 °), Vibration amplitude (displacement 30mm), Vibration frequency (1-100Hz) |
|
Resonance frequency | 2.4K HZ | |
Bandwidth (3DB) | 500HZ | |
Detection cycle | <100HZ | |
Cut-off frequency | <100HZ | |
Output rate | 5Hz, 15Hz, 35Hz, 50Hz can be set (RS485 does not have this function) |
|
Output signal | RS232/RS485/RS422/TTL optional | |
MTBF | ≥ 45000 hours/time | |
Impact resistance | 20000g, 2ms, 1/2sine | |
Anti-vibration | 10grms,10~1000Hz | |
Waterproof level | IP67 | |
Cable | Standard 1.5m length, wear-resistant, oil-proof, wide temperature, shielded cable 5*0.2mm2 | |
Weight | 65g (excluding packaging box) |