Customization: | Available |
---|---|
Type: | Servo |
Output Signal Type: | Digital Output |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Main performance index of the fiber-optic gyroscope:
Parameters | AC-1A | AC-1B | AC-1C | Unit |
Range | ±50 (10Ω) | g | ||
Threshold /Resolution | 1 | 2 | 3 | μg |
Bias K0/K1 | ≤ ±1 | ≤ ±3 | ≤ ±5 | mg |
Scale factor K1 | 1.05 ~ 1.30 | mA/g | ||
Class II nonlinearity coefficient K2/K1 | ≤ ±10 | ≤ ±15 | ≤ ±20 | μg/g2 |
0g 4 hours short time stability | ≤10 | ≤10 | ≤15 | μg |
1g 4 hours short time stability | ≤10 | ≤10 | ≤15 | ppm |
Bias drift Sigma K0 (1σ, one month) |
≤10 | ≤20 | ≤30 | μg |
Repeatability of scale factor Sigma σK1/K1 (1σ, one month) |
≤15 | ≤30 | ≤50 | ppm |
Class II nonlinearity Coefficient repeatability σK2/K1 (1σ, one month) |
≤ ±10 | ≤ ±20 | ≤ ±30 | μg/g2 |
Bias thermal coefficient | ≤ ±10 | ≤ ±30 | ≤ ±50 | μg/ºC |
Scale factor thermal coefficient | ≤ ±10 | ≤ ±30 | ≤ ±50 | ppm/ºC |
Noise (sample resistance 840Ω) | ≤5 | ≤8.4 | ≤8.4 | mv |
Natural Frequency | 400 ~ 800 | Hz | ||
Bandwidth | 800 ~ 2500 | Hz | ||
Vibration | 6g | Hz | ||
Shock | 100g | 8ms, 1/2s in | ||
Temperature range (Operating) | -55 ~ +85 | ºC | ||
Temperature range (saved) | -60 ~ +120 | ºC | ||
Power | ±12 ~ ±15 | V | ||
Consume current | ≤ ±20 | mA | ||
Temp. sensor | PT1000/AD590 | Optional | ||
Size | Ф25.4X30 | mm | ||
Weight | ≤80 | g |